Practical nonconvex compressive sensing reconstruction of highly-accelerated 3D parallel MR angiograms

  • Authors:
  • Joshua Trzasko;Clifton Haider;Armando Manduca

  • Affiliations:
  • Center for Advanced Imaging Research, Mayo Clinic, Rochester, MN;Center for Advanced Imaging Research, Mayo Clinic, Rochester, MN;Center for Advanced Imaging Research, Mayo Clinic, Rochester, MN

  • Venue:
  • ISBI'09 Proceedings of the Sixth IEEE international conference on Symposium on Biomedical Imaging: From Nano to Macro
  • Year:
  • 2009

Quantified Score

Hi-index 0.00

Visualization

Abstract

In this work, a nonconvex Compressive Sensing model targeted at true 3D reconstructions of highly undersampled MR angiograms acquired with parallel imaging is proposed. When combined with the Max-CAPR acquisition sequence, it is demonstrated that high quality, non-view-shared, 3D images of the contrast-filled neurovasculature can be acquired (at acceleration factors exceeding the number of coils) in just over 2 seconds and reconstructed in as few as 14 minutes on a high-performance workstation.