Markov random field modeling in computer vision
Markov random field modeling in computer vision
An approach to 2D/3D registration of a vertebra in 2D X-ray fluoroscopies with 3D CT images
CVRMed-MRCAS '97 Proceedings of the First Joint Conference on Computer Vision, Virtual Reality and Robotics in Medicine and Medial Robotics and Computer-Assisted Surgery
Post-Operative Measurement of Acetabular Cup Position Using X-Ray/CT Registration
MICCAI '00 Proceedings of the Third International Conference on Medical Image Computing and Computer-Assisted Intervention
Registration of Planar Film Radiographs with Computed Tomography
MMBIA '96 Proceedings of the 1996 Workshop on Mathematical Methods in Biomedical Image Analysis (MMBIA '96)
IPMI'05 Proceedings of the 19th international conference on Information Processing in Medical Imaging
2D/3D registration for measurement of implant alignment after total hip replacement
MICCAI'06 Proceedings of the 9th international conference on Medical Image Computing and Computer-Assisted Intervention - Volume Part II
Hi-index | 0.00 |
Similarity measure is one of the main factors that affect the accuracy of intensity-based 2D/3D registration of X-ray fluoroscopy to CT images. Information theory has been used to derive similarity measure for image registration leading to the introduction of mutual information, an accurate similarity measure for multi-modal and mono-modal image registration tasks. However, it is known that the standard mutual information measure only takes intensity values into account without considering spatial information and its robustness is questionable. Previous attempt to incorporate spatial information into mutual information either requires computing the entropy of higher dimensional probability distributions, or is not robust to outliers. In this paper, we show how to incorporate spatial information into mutual information without suffering from these problems. Using a variational approximation derived from the Kullback-Leibler bound, spatial information can be effectively incorporated into mutual information via energy minimization. The resulting similarity measure has a least-squares form and can be effectively minimized by a multi-resolution Levenberg-Marquardt optimizer. Experimental results are presented on datasets of two applications: (a) intra-operative patient pose estimation from a few (e.g. 2) calibrated fluoroscopic images, and (b) post-operative cup alignment estimation from single X-ray radiograph with gonadal shielding.