Algorithm for blood-vessel segmentation in 3D images based on a right generalized cylinder model: application to carotid arteries

  • Authors:
  • Leonardo Flórez Valencia;Jacques Azencot;Maciej Orkisz

  • Affiliations:
  • Pontificia Universidad Javeriana, Departamento de Ingeniería de Sistemas, Bogotá, Colombia;Université de Lyon, INSA-Lyon, CNRS, UMR, INSERM, CREATIS, Villeurbanne, France;Université de Lyon, INSA-Lyon, CNRS, UMR, INSERM, CREATIS, Villeurbanne, France

  • Venue:
  • ICCVG'10 Proceedings of the 2010 international conference on Computer vision and graphics: Part I
  • Year:
  • 2010

Quantified Score

Hi-index 0.00

Visualization

Abstract

The arterial lumen is modeled by a spatially continuous right generalized cylinder with piece-wise constant parameters. The method is the identifies the parameters of each cylinder piece from a series of planar contours extracted along an approximate axis of the artery. This curve is defined by a minimal path between the artery end-points. The contours are extracted by use of a 2D Fast Marching algorithm. The identification of the axial parameters is based on a geometrical analogy with piece-wise helical curves, while the identification of the surface parameters uses the Fourier series decomposition of the contours. Thus identified parameters are used as observations in a Kalman optimal estimation scheme that manages the spatial consistency from each piece to another. The method was evaluated on 15 datasets from the MICCAI 3D Segmentation in the Clinic Grand Challenge: Carotid Bifurcation Lumen Segmentation and Stenosis Grading (http://cls2009.bigr.nl/). The average Dice similarity score was 71.4.