  • Department of Biomedical Engineering, Boston University, Boston, USA and Multimodal Imaging Laboratory, Departments of Radiology and Neurosciences, University of California at San Diego, La Jolla, ...;Department of Neurology, Beth Israel Deaconess Medical Center, Boston, USA;Multimodal Imaging Laboratory, Departments of Radiology and Neurosciences, University of California at San Diego, La Jolla, USA;Institute for Psychology of the Hungarian Academy of Sciences, Budapest, Hungary;Department of Neurology, Massachusetts General Hospital, Boston, USA;Department of Neurology, Beth Israel Deaconess Medical Center, Boston, USA;Department of Biomedical Engineering, Boston University, Boston, USA;Multimodal Imaging Laboratory, Departments of Radiology and Neurosciences, University of California at San Diego, La Jolla, USA;Multimodal Imaging Laboratory, Departments of Radiology and Neurosciences, University of California at San Diego, La Jolla, USA

  • Venue:
  • Journal of Computational Neuroscience
  • Year:
  • 2010

Quantified Score

Hi-index 0.00

Visualization

Abstract

Forward solutions with different levels of complexity are employed for localization of current generators, which are responsible for the electric and magnetic fields measured from the human brain. The influence of brain anisotropy on the forward solution is poorly understood. The goal of this study is to validate an anisotropic model for the intracranial electric forward solution by comparing with the directly measured `gold standard'. Dipolar sources are created at known locations in the brain and intracranial electroencephalogram (EEG) is recorded simultaneously. Isotropic models with increasing level of complexity are generated along with anisotropic models based on Diffusion tensor imaging (DTI). A Finite Element Method based forward solution is calculated and validated using the measured data. Major findings are (1) An anisotropic model with a linear scaling between the eigenvalues of the electrical conductivity tensor and water self-diffusion tensor in brain tissue is validated. The greatest improvement was obtained when the stimulation site is close to a region of high anisotropy. The model with a global anisotropic ratio of 10:1 between the eigenvalues (parallel: tangential to the fiber direction) has the worst performance of all the anisotropic models. (2) Inclusion of cerebrospinal fluid as well as brain anisotropy in the forward model is necessary for an accurate description of the electric field inside the skull. The results indicate that an anisotropic model based on the DTI can be constructed non-invasively and shows an improved performance when compared to the isotropic models for the calculation of the intracranial EEG forward solution.