  • Bahce Vocational School of Higher Education, Osmaniye Korkutata University, Osmaniye, Turkey 80500;Faculty of Engineering and Information Technologies, International Burch University, Sarajevo, Bosnia and Herzegovina 71000;Faculty of Medicine, Department of Neurology, Kahramanmaras Sutcu Imam University, Kahramanmaraş, Turkey 46500

  • Venue:
  • Journal of Medical Systems
  • Year:
  • 2012

Quantified Score

Hi-index 0.00

Visualization

Abstract

Different kind of methods has been applied to detect the migraine by using flash stimulation. Especially frequency analysis of EEG signal is the most preferred method to detect the migraine by using flash stimulation. Different flash stimulation frequencies at wide frequency range have been used in migraine detection. But the effects of these flash stimulation frequencies and the most effective frequency can be determined by analyzing these frequencies separately. Since each stimulation frequency has been implemented in different time periods, it is necessary to determine the time period to detect magnitude increase in migraine patients. The aim of this study is to determine the most effective flash stimulation frequency and time duration to detect the migraine. In this study, we analyzed the flash stimulation frequencies and time duration separately for detecting migraine. Performance of each flash stimulation frequency has been determined to detect the migraine by analyzing the power spectrums obtained under 2 Hz, 4 Hz and 6 Hz and artificial neural network has been used to determine the which data has a superior performance. Afterwards we analyzed the 2 s, 4 s, 6 s, 8 s and 10 s of flash stimulation periods separately by observing the power spectrums and the results are verified by using artificial neural network. As a result of this study we proposed the 4 Hz of flash stimulation frequency is the most effective frequency and 8 s time period is necessary to detect the migraine at the beta band of EEG's T5-T3 channel.