Closed-Loop Performance Monitoring in the Presence of System Changes and Disturbances

  • Authors:
  • FREDRIK GUSTAFSSON;STEFAN F. GRAEBE

  • Affiliations:
  • Department of Electrical Engineering, Linköping University, S-581 83, Linköping, Sweden.;OMV, Mannswoertherstr. 28, A-2320 Schwechat, Austria

  • Venue:
  • Automatica (Journal of IFAC)
  • Year:
  • 1998

Quantified Score

Hi-index 22.15

Visualization

Abstract

This paper addresses issues in closed-loop performance monitoring. Particular attention is paid to detecting whether an observed deviation from nominal performance is due to a disturbance or due to a control relevant system change. This is achieved by introducing a novel performance measure that allows feasible application of a standard CUSUM change detector. The paper includes explicit results on the risk of mistaking a disturbance for a system change. The algorithm has been implemented in real time on a DSP and evaluated on a DC motor.