An efficient region of interest acquisition method for dynamic magnetic resonance imaging

  • Authors:
  • W. S. Hoge;E. L. Miller;H. Lev-Ari;D. H. Brooks;W. C. Karl;L. P. Panych

  • Affiliations:
  • Dept. of Electr. & Comput. Eng., Northeastern Univ., Boston, MA;-;-;-;-;-

  • Venue:
  • IEEE Transactions on Image Processing
  • Year:
  • 2001

Quantified Score

Hi-index 0.01

Visualization

Abstract

Motivated by work in the area of dynamic magnetic resonance imaging (MRI), we develop a new approach to the problem of reduced-order MRI acquisition. Efforts in this field have concentrated on the use of Fourier and singular value decomposition (SVD) methods to obtain low-order representations of an entire image plane. We augment this work to the case of imaging an arbitrarily-shaped region of interest (ROI) embedded within the full image. After developing a natural error metric for this problem, we show that determining the minimal order required to meet a prescribed error level is in general intractable, but can be solved under certain assumptions. We then develop an optimization approach to the related problem of minimizing the error for a given order. Finally, we demonstrate the utility of this approach and its advantages over existing Fourier and SVD methods on a number of MRI images