Multi-component heart reconstruction from volumetric imaging
Proceedings of the 2008 ACM symposium on Solid and physical modeling
Hi-index | 0.00 |
Activation time (AT) imaging from electrocardiographic mapping data is under development becoming feasible for clinical applications. In this study the AT imaging approach is applied to data of the human atria and ventricles in four patients. The reconstructed atrial AT pattern on the endo- and epicardium for paced rhythm data was compared with the CARTO庐 map. The geometrical error between the modelled right atrial (RA) target chamber and the anatomical CARTO庐 map was between 4 and 7mm. With regard to the localization error we compared the locations of the first (endocardial) breakthroughs determined from the reconstructed AT map and from the CARTO庐 map within RA. This localization error was identified to be within 6 and 13mm.