A new bonding-tool solution to improve stitch bondability

  • Authors:
  • K. S. Goh;Z. W. Zhong

  • Affiliations:
  • SPT Asia Pte Ltd., 970 Toa Payoh North, #07-25/26, Singapore 318992, Singapore;School of Mechanical and Aerospace Engineering, Nanyang Technological University, 50 Nanyang Avenue, Singapore 639798, Singapore

  • Venue:
  • Microelectronic Engineering
  • Year:
  • 2007

Quantified Score

Hi-index 2.88

Visualization

Abstract

A new bonding-tool solution is proposed to improve stitch bondability by creating a new surface morphology on the tip surface of a wire-bonding tool (capillary). The surface has relatively deep lines with no fixed directions. This new capillary has less slipping between the wire and the capillary tip surface and provides better coupling effect between them. Experiments of wire bonding on unstable lead frames/substrates, alloyed wire (2N gold wire) bonding, and copper wire bonding were carried out to confirm the effect of the new capillary on the stitch bondability. The experimental results are promising and have proved that the use of the new capillary could improve the bondability of the stitch bond and minimize the occurrence of short tail defects and non-sticking on lead during bonding.