The NURBS book
ICCV '05 Proceedings of the Tenth IEEE International Conference on Computer Vision - Volume 2
Dynamic Model-Driven Quantitative and Visual Evaluation of the Aortic Valve from 4D CT
MICCAI '08 Proceedings of the 11th international conference on Medical Image Computing and Computer-Assisted Intervention - Part I
Complete valvular heart apparatus model from 4D cardiac CT
MICCAI'10 Proceedings of the 13th international conference on Medical image computing and computer-assisted intervention: Part I
Computational decision support for percutaneous aortic valve implantation
MIAR'10 Proceedings of the 5th international conference on Medical imaging and augmented reality
Detection of 3D spinal geometry using iterated marginal space learning
MCV'10 Proceedings of the 2010 international MICCAI conference on Medical computer vision: recognition techniques and applications in medical imaging
Patient-specific modeling of heart valves: from image to simulation
FIMH'13 Proceedings of the 7th international conference on Functional Imaging and Modeling of the Heart
Hi-index | 0.00 |
The anatomy, function and hemodynamics of the aortic and mitral valves are known to be strongly interconnected. An integrated quantitative and visual assessment of the aortic-mitral coupling may have an impact on patient evaluation, planning and guidance of minimal invasive procedures. In this paper, we propose a novel model-driven method for functional and morphological characterization of the entire aortic-mitral apparatus. A holistic physiological model is hierarchically defined to represent the anatomy and motion of the two left heart valves. Robust learning-based algorithms are applied to estimate the patient-specific spatial-temporal parameters from four-dimensional TEE and CT data. The piecewise affine location of the valves is initially determined over the whole cardiac cycle using an incremental search performed in marginal spaces. Consequently, efficient spectrum detection in the trajectory space is applied to estimate the cyclic motion of the articulated model. Finally, the full personalized surface model of the aortic-mitral coupling is constructed using statistical shape models and local spatial-temporal refinement. Experiments performed on 65 4D TEE and 69 4D CT sequences demonstrated an average accuracy of 1.45mm and speed of 60 seconds for the proposed approach. Initial clinical validation on model-based and expert measurement showed the precision to be in the range of the inter-user variability. To the best of our knowledge this is the first time a complete model of the aortic-mitral coupling estimated from TEE and CT data is proposed.