The Visual Hull Concept for Silhouette-Based Image Understanding
IEEE Transactions on Pattern Analysis and Machine Intelligence
A convenient multicamera self-calibration for virtual environments
Presence: Teleoperators and Virtual Environments
A survey of advances in vision-based human motion capture and analysis
Computer Vision and Image Understanding - Special issue on modeling people: Vision-based understanding of a person's shape, appearance, movement, and behaviour
Real-Time 3D Reconstruction for Collision Avoidance in Interventional Environments
MICCAI '08 Proceedings of the 11th International Conference on Medical Image Computing and Computer-Assisted Intervention, Part II
A boosted segmentation method for surgical workflow analysis
MICCAI'07 Proceedings of the 10th international conference on Medical image computing and computer-assisted intervention - Volume Part I
Probabilistic deformable surface tracking from multiple videos
ECCV'10 Proceedings of the 11th European conference on Computer vision: Part IV
Robust background subtraction for quick illumination changes
PSIVT'06 Proceedings of the First Pacific Rim conference on Advances in Image and Video Technology
Hi-index | 0.00 |
In the last decade the use of interventional X-ray imaging, especially for fluoroscopy-guided procedures, has increased dramatically. Due to this the radiation exposure of the medical staff has also increased. Although radiation protection measures such as lead vests are used there are still unprotected regions, most notably the hands and the head. Over time these regions can receive significant amounts of radiation. In this paper we propose a system for approximating the radiation exposure of a physician during surgery. The goal is to sensibilize physicians to their radiation exposure and to give them a tool to quickly check it. To this end we use a real-time 3D reconstruction system which builds a 3D-representation of all the objects in the room. The reconstructed 3D- representation of the physician is then tracked over time and at each time step in which the X-Ray source is used the radiation received by each body part is accumulated. To simulate the radiation we use a physics-based simulation package. The physician can review his radiation exposure after the intervention and use the collected radiation information over a longer time period in order to minimize his radiation exposure by adjusting his positioning relative to the X-ray source. The system can also be used as an awareness tool for less experienced physicians.