Easy parameterized verification of biphase mark and 8n1 protocols

  • Authors:
  • Geoffrey M. Brown;Lee Pike

  • Affiliations:
  • Indiana University, Bloomington;Galois Connections

  • Venue:
  • TACAS'06 Proceedings of the 12th international conference on Tools and Algorithms for the Construction and Analysis of Systems
  • Year:
  • 2006

Quantified Score

Hi-index 0.00

Visualization

Abstract

The Biphase Mark Protocol (BMP) and 8N1 Protocol are physical layer protocols for data transmission. We present a generic model in which timing and error values are parameterized by linear constraints, and then we use this model to verify these protocols. The verifications are carried out using SRI's SAL model checker that combines a satisfiability modulo theories decision procedure with a bounded model checker for highly-automated induction proofs of safety properties over infinite-state systems. Previously, parameterized formal verification of real-time systems required mechanical theorem-proving or specialized real-time model checkers; we describe a compelling case-study demonstrating a simpler and more general approach. The verification reveals a significant error in the parameter ranges for 8N1 given in a published application note [1].